Amplifier Analyzer AOIP AOIP Calibrator AOIP Calys AOIP Viet Nam Bài giảng LabView Balance Bản tin công nghệ Biến tần-Khởi động mềm blogger_ino Calibrator Cảm biến chuyên dụng Takex DX-S35F – DX-S33C – Phase Diffrential Detection BGS Sensors – Takex Việt Nam Cảm biến quang AECO FT18SM-CP50 – Photoelectric Sensors AECO – AECO Viet Nam Cảm biến quang AECO FTQSP – Photoelectric Sensors AECO – AECO Viet Nam Cảm biến quang IFM – Photoelectric Sensor IFM O1D100 – IFM Việt Nam – INO Việt Nam Cảm biến siêu âm Takex US-1AH / US-1AHPN – Ultrasonic Sensers – Takex Viet Nam Cảm biến siêu âm Takex US-S25AN – Takex Viet Nam – INO Việt Nam Cảm biến siêu âm Takex US-T04AN – Ultrasonic Sensers – Takex Viet Nam – INO Việt Nam Cảm biến siêu âm Takex US-T50 / US-R25 – Ultrasonic Sensers – Takex Viet Nam – INO Việt Nam Cảm biến siêu âm Takex US-U30AN – Takex Viet Nam – INO Việt Nam Cảm biến siêu âm Takex USA-S1AN / USA-S3MAN / USA-S6AN – Ultrasonic Displacement Sensers – Takex Viet Nam Cảm biến siêu âm Takex VS-S50RNF / VS-S20R / VS-S20B / VS-S15W / VS-S15WNF / VS-S15RBNF – BGS Photodiode Array Sensers – Takex Viet Nam Cảm biến sợi quang Takex F1R – F1RPN – F1RH – F1RHPN – F1RM – F1RMPN – F1RH-J – F11R – F11CR – F11CRPN – Digital Display Fiber Optic Sensors – Takex Viet Nam Cảm biến sợi quang Takex F70RK – F70GK – F70BK – F70WK – F70RKPN – F70GKPN – F70BKPN – F70WKPN – Fiber Optic Sensors – Takex Viet Nam Cảm biến sợi quang Takex F80R – F80RPN – Digital Display Fiber Optic Sensors – Takex Viet Nam Cảm biến vị trí AECO – Cảm biến cảm ứng AECO SMF – M12 – M18 – M30 – Metalface Inductive Sensors – AECO Việt Nam Cảm biến vị trí AECO – Cảm biến điện dung AECO SC18SP – SC30SM – Capacitive Sensors – AECO Việt Nam Cảm biến vị trí AECO – Cảm biến điện dung AECO SC30SP – SC30M – Capacitive Sensors – AECO Việt Nam Cảm biến vị trí AECO – Cảm biến từ AECO SI12SM – Inductive Sensors – AECO Việt Nam Cảm biến vị trí AECO – Cảm biến từ AECO SIP12 – SIQ80 – Inductive Sensors – AECO Việt Nam Controller Counter/Timer Data Acquisition System Đếm xung và đếm số vòng quay của động cơ bằng encoder ElCO và PLC S7-300 – ELCO Việt Nam Dịch vụ Điều Khiển-Giám Sát Đo các đại lượng điện Đo lực-Momen Đo Lường-Kiểm Tra Đo quang-Âm thanh Download featuredpost featuredpost/sản phẩm Form-Biểu mẫu Giới thiệu Hiệu chuẩn-Cân chỉnh HMI Siemens – Biến Tần Siemens – Simatic Siemens – Module Siemens – Siemens Việt Nam IFTTT INO Việt Nam Khác Khoảng cách-Vị trí LabView Linh kiện thiết bị khác Lưu lương-Mức Meter Mỹ áp thuế khủng gần 800% lên thép Nga National Instruments – Integrated 266 MHz Real-Time Controller and 2M Gate FPGA (Model: NI cRIO-9073) Nhiệt độ-Áp suất Oscilloscope Phần mềm LabView Phân tích-Thử nghiệm PLC-HMI Power Supply Sản phẩm Sản phẩm - Dự án Sản phẩm nổi bật Sản-phẩm-nổi-bật Sensor Signal Generator Súng bắn nhiệt Fluke – Máy chụp nhiệt Fluke – Fluke Việt Nam – INO Việt Nam Switch Tài liệu LabView Technical Document Tin tức Tin tức - Sự kiện Tự Động-Đóng Cắt Twitter wordpress YouTube

AOIP- Safety Tester Tool for Boiler Maintenance (Model:UniGas 1000 P+T)

Sản phẩm » Other

UNIGAS1000PT_200
Tên sản phẩm:

AOIP- Safety Tester Tool for Boiler Maintenance (Model:UniGas 1000 P+T)

Mã số:1582
Hãng sản xuất:AOIP
Chủng loại sản phẩm:Other
Ngày cập nhật:26/02/2014
Giá:Call


MÔ TẢ SẢN PHẨM

 Description:
UniGas 1000 P+T has been designed for the gas network installation and plant maintenance technicians demand. It's a compact, rugged, modular and simple-to-use instrument. The pressure range is from -10 up to 120 mbar (automatically compensating the ambient temperature changes) and it comes with a procedure for the gas network leak detection. 

The Unigas 1000 P+T can be used for a wide variety of test and measurements: the pressure and temperature measurement, the leak testing, etc...
  • Gas leak detector (sniffer) simply connecting the probe to measure the gas leaks working with one instrument only.
  • Ambient CO monitoring for working in safety places.
  • Long draft measurements (±200 Pa, 0.1 Pa) for natural draft boiler.
The wide backlit LCD display and the built-in impact printer let you display and print all your measurements and your test reports.
Specification:
  • Differential pressure internal sensor:
    • Range : -10...120 hPa
    • Resolution : 0.01 hPa
    • Accuracy : ±3 Pa <300 Pa
    • ±1% rdg. >300 Pa
  • Gas pipework pressure internal sensor:
    • Range: -10...120 mBar
    • Resolution: 0.1 mBar
    • Accuracy : ±1% of the reading
    • Program for the pressure decay leaks
  • Low pressure external probe for draft measurements:
    • Range: ±200 Pa
    • Resolution: 0.1 Pa
    • Accuracy : ±1% of the reading
    • Chimney probe kit
  • Tc K thermometer:
    • Range: 0 a +600°C
    • Resolution: 0.1 °C
    • Accuracy : ±(0.3% rdg.+0.3°C)
  • Ambient temperature:
    • Internal sensor: Pt100
    • Range: -10 to +100°C
    • Resolution : 0.1 °C
    • Accuracy: ±(0.2% rdg.+0.15°C)
  • Power supply: High capacity Mi-MH rechargeable battery pack
  • Charging time: 8h at 90% with instrument off
  • Battery life: 6 hours (typical) continuous use (without printing and backlight).
  • Printer: Internal impact type 24 columns with paper roll. (10m)
  • Printer power supply: from the analyser battery pack.
  • Printed report header: 4 programmable lines.
  • Display: 40x58 mm alpha-numeric LCD with backlight device.
  • Infrared port: compatible with HP82240B cordless printer.
  • Operating temperature: from -5°C to +45°C - from -10 to 90% RH
  • Storage temperature: from -20 to +50°C (3 months maximum at temperatures exceeding the operational limits).
  • Dimensions and Weight: 115x90x330 mm - 1.1 kg with battery and printer
UNIGAS 1000 P+T - 8204 - A - B - C - D
  • A - Pressure Sensors
    • 1 - 100hPa internal differential sensor
    • 2 - 200Pa external draft probe (with chimney probe kit)
  • B - Mains adapter / charger
    • 1 - 115V ±10% 50/60Hz - USA plug
    • 2 - 230V ±10% 50/60Hz - Schuko plug
    • 3 - 230V ±10% 50/60Hz - UK plug
    • 4 - 230V ±10% 50/60Hz - Europe plug
    • 5 - 100V ±10% 50/60Hz - USA/Japan plug
  • C - Options (up to 7 elective)
    • 1 - Built-in impact printer
    • 2 - External probe for gas leak detector (sniffer)
    • 3 - External CO ambient probe for monitoring
    • 5 - Leak test KIT (pump+hose+adapters)
    • 7 - ABS carrying case
    • 9 - DBGas 2004 STANDARD software
    • A - A combustion analyser transformer kit (O2 + CO)
  • D - Calibration certificate
    • 1 - Eurotron attributed EA
  • X - Instruction manual
    • ENG - English