Amplifier Analyzer AOIP AOIP Calibrator AOIP Calys AOIP Viet Nam Bài giảng LabView Balance Bản tin công nghệ Biến tần-Khởi động mềm blogger_ino Calibrator Cảm biến chuyên dụng Takex DX-S35F – DX-S33C – Phase Diffrential Detection BGS Sensors – Takex Việt Nam Cảm biến quang AECO FT18SM-CP50 – Photoelectric Sensors AECO – AECO Viet Nam Cảm biến quang AECO FTQSP – Photoelectric Sensors AECO – AECO Viet Nam Cảm biến quang IFM – Photoelectric Sensor IFM O1D100 – IFM Việt Nam – INO Việt Nam Cảm biến siêu âm Takex US-1AH / US-1AHPN – Ultrasonic Sensers – Takex Viet Nam Cảm biến siêu âm Takex US-S25AN – Takex Viet Nam – INO Việt Nam Cảm biến siêu âm Takex US-T04AN – Ultrasonic Sensers – Takex Viet Nam – INO Việt Nam Cảm biến siêu âm Takex US-T50 / US-R25 – Ultrasonic Sensers – Takex Viet Nam – INO Việt Nam Cảm biến siêu âm Takex US-U30AN – Takex Viet Nam – INO Việt Nam Cảm biến siêu âm Takex USA-S1AN / USA-S3MAN / USA-S6AN – Ultrasonic Displacement Sensers – Takex Viet Nam Cảm biến siêu âm Takex VS-S50RNF / VS-S20R / VS-S20B / VS-S15W / VS-S15WNF / VS-S15RBNF – BGS Photodiode Array Sensers – Takex Viet Nam Cảm biến sợi quang Takex F1R – F1RPN – F1RH – F1RHPN – F1RM – F1RMPN – F1RH-J – F11R – F11CR – F11CRPN – Digital Display Fiber Optic Sensors – Takex Viet Nam Cảm biến sợi quang Takex F70RK – F70GK – F70BK – F70WK – F70RKPN – F70GKPN – F70BKPN – F70WKPN – Fiber Optic Sensors – Takex Viet Nam Cảm biến sợi quang Takex F80R – F80RPN – Digital Display Fiber Optic Sensors – Takex Viet Nam Cảm biến vị trí AECO – Cảm biến cảm ứng AECO SMF – M12 – M18 – M30 – Metalface Inductive Sensors – AECO Việt Nam Cảm biến vị trí AECO – Cảm biến điện dung AECO SC18SP – SC30SM – Capacitive Sensors – AECO Việt Nam Cảm biến vị trí AECO – Cảm biến điện dung AECO SC30SP – SC30M – Capacitive Sensors – AECO Việt Nam Cảm biến vị trí AECO – Cảm biến từ AECO SI12SM – Inductive Sensors – AECO Việt Nam Cảm biến vị trí AECO – Cảm biến từ AECO SIP12 – SIQ80 – Inductive Sensors – AECO Việt Nam Controller Counter/Timer Data Acquisition System Đếm xung và đếm số vòng quay của động cơ bằng encoder ElCO và PLC S7-300 – ELCO Việt Nam Dịch vụ Điều Khiển-Giám Sát Đo các đại lượng điện Đo lực-Momen Đo Lường-Kiểm Tra Đo quang-Âm thanh Download featuredpost featuredpost/sản phẩm Form-Biểu mẫu Giới thiệu Hiệu chuẩn-Cân chỉnh HMI Siemens – Biến Tần Siemens – Simatic Siemens – Module Siemens – Siemens Việt Nam IFTTT INO Việt Nam Khác Khoảng cách-Vị trí LabView Linh kiện thiết bị khác Lưu lương-Mức Meter Mỹ áp thuế khủng gần 800% lên thép Nga National Instruments – Integrated 266 MHz Real-Time Controller and 2M Gate FPGA (Model: NI cRIO-9073) Nhiệt độ-Áp suất Oscilloscope Phần mềm LabView Phân tích-Thử nghiệm PLC-HMI Power Supply Sản phẩm Sản phẩm - Dự án Sản phẩm nổi bật Sản-phẩm-nổi-bật Sensor Signal Generator Súng bắn nhiệt Fluke – Máy chụp nhiệt Fluke – Fluke Việt Nam – INO Việt Nam Switch Tài liệu LabView Technical Document Tin tức Tin tức - Sự kiện Tự Động-Đóng Cắt Twitter wordpress YouTube

AOIP-Electrolytic starters (LRS) for slipring motors from 550 to 20,000 kW (Model:EPM)

Sản phẩm » Other

EPM_280x194
Tên sản phẩm:

AOIP-Electrolytic starters (LRS) for slipring motors from 550 to 20,000 kW (Model:EPM)

Mã số:1576
Hãng sản xuất:AOIP
Chủng loại sản phẩm:Other
Ngày cập nhật:26/02/2014
Giá:Call


MÔ TẢ SẢN PHẨM

 EPM electrolytic starters can be used to start slipring motors from 500 kW to 20,000 kW. They will supply the power necessary to drive the motor by resistance variation. Designed for controlled starting and speed control of large slipring motors in demanding applications, the EPM liquir rotor starters ensure a smooth progressive acceleration of installations such as:
  • Ventilation
  • Crushing
  • Milling
  • Conveyors
  • Pumps...
They are widely used in various industries such as mines, quarries, cement plants, water treatment and associated industries. They are also adapted to specific applications such as car fragmentisers, plastic mixers and sugar cane knives. 
Several models and options are available according to the starting power required, the inertia of the driven machine and the application. Feel free to contact us and explain us about your requirements (Use the section Necessary information to quote a starter), our staff will quote the suitable starter and the eventual necessary options.
You will find below the description of an EPM starter and its operating principle.

Necessary information to quote a starter


Driven machine:
  • Type (Crusher, conveyor…)
  • Rotor data: Motor power, rotor voltage, rotor current
  • Motor speed in tr / min
  • Single or dual assembly
Ambient temperature: Minimum, maximum and average value
Starting time in s
Temps de démarrage : en secondes
Starting torge: Cn
Number of starts per hour
Number of consecutive starts
Country of destination

Electrical features:

ReferenceMaximum power
Tstarter / Tnominal = 0.7Tstarter / Tnominal = 1Tstarter / Tnominal = 1.4Tstarter / Tnominal = 2
EPM1/11,600 kW1,100 kW790 kW550 kW
EPM2/12,600 kW1,800 kW1,300 kW900 kW
EPM3/15,200 kW3,700 kW2,600 kW1,850 kW
EPM3/26,400 kW4,500 kW3,200 kW2,250 kW
EPM4/17,800 kW5,500 kW3,900 kW2,750 kW
EPM4/213,000 kW9,100 kW6,500 kW4,550 kW
EPM1/1 DUO2 x 1,600 kW2 x 1,100 kW2 x 790 kW2 x 550 kW
EPM2/1 DUO2 x 2,600 kW2 x 1,800 kW2 x 1,300 kW2 x 900 kW
EPM3/1 DUO2 x 5,200 kW2 x 3,700 kW2 x 2,600 kW2 x 1,850 kW
EPM3/2 DUO2 x 6,400 kW2 x 4,500 kW2 x 3,200 kW2 x 2,250 kW
EPM3/1 DUO2 x 7,800 kW2 x 5,500 kW2 x 3,900 kW2 x 2,750 kW
EPM4/2 DUO 2 x 9,100 kW2 x 6,500 kW2 x 4550 kW
Maximum power of engine given for 1 start/hour and 3 consecutive starts from cold state.
Different models exist to suit the power of the starter(s) and the inertia of the driven machine.
The ranges of EPM starters given above are theoretical only, as ranges will depend on many further non negligible parameters such as starting conditions, starting time and cadenza, torque, type and load of the driven machine, ambient temperature…
Rotor voltage between rings: 3,500 V max
Standard starting times: 20, 30, 40, 60, 80, 130 s factory preset
Level of electrolyte monitored by magnetic floating system
Electrolyte temperature monitored by thermostats
Electrolyte cooling down by natural convection and agitator mixing
Low current density of electrodes: about 1 A/cm².

Further features



Démarreur EPM DUO
When starting machines of large powers, or in order to reduce mechanical stress, it is sometimes preferable to use two starters totaling the rated power rather than a single one.
An EPM DUO starter is then used, to ensure identical acceleration of both motors.
The EPM DUO consists in two resistances whose ohmic values are equalized between the two tanks. The electrode drive assemblies are mechanically coupled, so as to ensure complete synchronization of the movement of the two electrode assemblies, which are driven by a common geared motor.
The two resistances are finally shorted out by a single four or six pole shorting contactor, at the end of the run-up period.
EPM starter with heat exchangerAn EPM starter equipped with a heat exchanger is suitable for applications requiring:
- high starting cadenza
- speed variation or permanent sliding of the engine
An exchanging system can be mounted on any EPM started, with the addition of a regulation servo-motor and a heat exchanger.
Heat dissipation and capacity are increased significantly.
This option requires an onsite supply of cool water.
ElectrolyteComposition: In powder or crystal form for mixing with drinking water and anti-evaporation oil
Electrolyte temperature is controlled by thermostat 16 A/400 V.
Electrolyte level: level is visible through transparency of tanks.
Antigel (option)Protection down to -20°C
It has to be inserted into the electrolyte before commissioning since it alters its resistivity. Il can be used throughout the year.